NewSale
Honeywell MC-TDIA22 51304431-175 Digital Input Field Termination Assembly
Honeywell MC-TDIA22 51304431-175 Digital Input Field Termination Assembly Original price was: $631.00.Current price is: $514.00.
MC-TDID52 Honeywell Digital Input Field Termination Assembly
MC-TDID52 Honeywell Digital Input Field Termination Assembly Original price was: $631.00.Current price is: $514.00.

Honeywell MC-TAIH03 51309136-175 High-Level Analog Input Field Termination Assembly. Brand New, Original Stock, with Global Shipping.

10 in stock

Sku:MC-TAIH03 51309136-175

10 in stock

Overview

Honeywell MC-TAIH03 High-Level Analog Input Field Termination Assembly

Configured for terminating and routing high-level analog field signals in Honeywell DCS systems, the Honeywell MC-TAIH03 51309136-175 (MC-TAIH03 High-Level Analog Input Field Termination Assembly) provides direct physical and electrical field-to-controller signal connection. The assembly supports 16 analog input channels and interfaces high-level signals, including typical 4-20 mA current loops and 0-10 V signals, with compatible Honeywell Experion PKS and Experion LX platforms.

Hardware Specifications

ParameterSpecification
ModelMC-TAIH03
Part Number51309136-175
BrandHoneywell
Device TypeHigh-Level Analog Input Field Termination Assembly (FTA)
Number of Channels16 analog input channels
Input Signal TypeHigh-level analog signals
Typical Signal Ranges4-20 mA and 0-10 V
System CompatibilityHoneywell Experion PKS / Experion LX DCS
OriginUSA
WeightApprox. 0.3 kg
DimensionsApprox. 150 mm x 80 mm x 15 mm
Operating Temp-40 deg C to +70 deg C

4-20 mA Process Signal Termination

The MC-TAIH03 51309136-175 terminates field-side high-level analog circuits and routes each connected signal toward the associated controller input interface. Therefore, technicians can organize multiple analog loops through a dedicated termination assembly rather than routing individual field conductors directly to the controller hardware.

For 4-20 mA instrumentation circuits, installation practices should preserve loop polarity and maintain separation between analog signal wiring and sources of electrical interference. The provided specifications identify high-level analog signal handling; however, they do not define HART communication support or channel-to-channel isolation characteristics. These functions should therefore not be assumed without the applicable Honeywell system documentation.

Frequently Asked Questions

Q: How many analog input channels does the MC-TAIH03 51309136-175 provide?
A: The assembly provides 16 analog input channels.

Q: What field signal types can be connected to this FTA?
A: The provided data identifies high-level analog signals, including typical 4-20 mA current loops and 0-10 V signals.

Q: Does the MC-TAIH03 51309136-175 consume a specified operating power load?
A: The provided technical data does not specify a power consumption value. The installation documentation for the associated Honeywell I/O system should be checked before calculating cabinet power loading.

Field Installation Guidelines

Mount the MC-TAIH03 51309136-175 according to the mechanical arrangement specified for the associated Honeywell I/O assembly.

Verify conductor identification and analog loop polarity before terminating field wiring.

Keep analog signal conductors separated from high-voltage power wiring, switching circuits, and other potential electromagnetic interference sources.

Terminate cable shields according to the applicable Honeywell system grounding architecture. Avoid creating unintended multiple shield-ground paths.

Confirm terminal tightness and inspect each channel connection before energizing the associated control system.

After installation, verify the measured analog input value at the controller level against the field signal and confirm correct channel assignment.

Honeywell Top Products

TDC3000FC-/FSTDC3000
8C-TAIDA1FC-TSAI-1620M51107403-100
8C-TAIDB1FC-SDI-162451109394-100
8U-TAIXB1FC-SDO-082451109516-100
8C-PCNT01FC-SDO-162451109620-200
8U-TAIXA1FC-TSDI-162451120673-101
8C-TAIXB1FC-TSDO-162451120841-101
8C-TAOX61FC-IO-0001 51121227-101
8C-TCNT01FC-RUSIO-322451153818-103
8U-PWSP04FC-PSU-24051651153818-201
8U-PWSP05FC-SAI-1620m51155128-200

Customers Also Viewed

Bently NevadaABBYokogawaWoodwardSchneider
133835-02SPS02SPS025501-365140CPS12420
135321-01SPS03-5VSPS03-5V5501-367140NOE77101
135322-01SPS03-15VSPS03-15V9907-031140DAI55300
136751-01SPNIS21SPNIS215503-198140CRP93100
136751-02SPBRC410SPBRC4105464-658140AVI03000
184139-10SPNPM22SPNPM229907-023140CPS11420
82362-01SPDSO14SPDSO149907-162BMXDDI1602
84134-01SPFEC12SPFEC129907-028BMXNOM0200
87900-02SPDSI14SPDSI148200-1302BMXAMO0410
89998-01SPAS011SPAS0118406-003BMXAMI0810

Contact: Manski Wong +86 18030205725 manski@cambia.cn

Weight0.3 kg
Dimensions150 × 80 × 15 mm

Reviews

There are no reviews yet.

Be the first to review “Honeywell MC-TAIH03 High-Level Analog Input Field Termination Assembly”

Your email address will not be published. Required fields are marked *

Back to Top