NewSale
102550-01 Bently Nevada Monitor Main Module
102550-01 Bently Nevada Monitor Main Module Original price was: $634.00.Current price is: $528.00.
3500/05-02-04-00-00-01 Bently Nevada System Rack
3500/05-02-04-00-00-01 Bently Nevada System Rack Original price was: $634.00.Current price is: $528.00.
ADRE 208-P 102351-04-01 Data Acquisition Interface Unit, Brand New and Original Stock. Supports Global Shipping.

28 in stock

Sku:102351-04-01

28 in stock

Overview 

Configured for machinery vibration data acquisition in the ADRE system, the Bently Nevada ADRE 208-P 102351-04-01 (ADRE 208-P Data Acquisition Interface Unit) provides direct physical and electrical execution for multi-channel signal acquisition and communication with compatible analysis hardware. The unit supports up to 8 signal inputs per interface unit, while compatible ADRE 208-P configurations can support up to 16 channels.

Hardware Specifications

ParameterSpecification
ModelADRE 208-P 102351-04-01
Base ModelADRE 208-P
Product TypeData Acquisition Interface Unit
BrandBently Nevada
ManufacturerBently Nevada
OriginUSA
Weight0.16 kg
Dimensions2 x 19 x 12.8 cm
Signal Inputs8 signal inputs
Channel CapabilityUp to 16 channels in compatible ADRE 208-P configurations
Communication InterfaceEnhanced parallel port for connection to ADRE 208-P DAIUs
Storage Requirement80 MB hard disk space
Display FunctionReal-time display capability
Database CompatibilityBackwards compatible with existing ADRE 3 databases

Machinery Signal Acquisition and Rotor Dynamics

The ADRE 208-P 102351-04-01 forms part of a machinery measurement chain that acquires dynamic signals for waveform and rotor behavior analysis. Therefore, signal routing and channel identification should remain consistent throughout the acquisition configuration.

For eddy-current measurement channels, probe scaling and associated signal conditioning must match the installed transducer system. Incorrect scaling can alter displacement interpretation during subsequent analysis.

Where proximity measurements are included, gap voltage validation may also be performed against the applicable transducer system target. A nominal -10 VDC target is commonly used as a reference point in compatible Bently Nevada eddy-current measurement practices, although the applicable probe and Proximitor system documentation controls the final acceptance value.

In addition, maintain physical separation between signal cables and high-energy conductors. Correct shielding and grounding practices help reduce cross-talk and unwanted interference between adjacent acquisition channels.

Frequently Asked Questions

Q: How many signal inputs does the Bently Nevada ADRE 208-P 102351-04-01 provide?
A: The provided specification identifies 8 signal inputs for the ADRE 208-P 102351-04-01. Compatible system configurations can support up to 16 channels.

Q: Can the ADRE 208-P 102351-04-01 work with existing ADRE 3 databases?
A: Yes. The provided information specifies backwards compatibility with existing ADRE 3 databases.

Q: Does the provided specification define the operating temperature or power consumption?
A: No. The supplied technical data does not specify operating temperature or power consumption. Installation should therefore follow the environmental and electrical limits defined in the applicable Bently Nevada ADRE system documentation.

Field Installation Guidelines

Mount the ADRE 208-P 102351-04-01 according to the applicable equipment installation arrangement and ensure that the unit is protected from mechanical stress during handling.

Connect acquisition channels according to the assigned signal configuration. Verify channel identification before recording or displaying machinery data.

Route low-level measurement cables separately from motor feeders, switching circuits, and other high-current conductors. Where shielded cables are specified, terminate the shield according to the applicable system grounding practice to reduce noise and cross-talk.

Inspect connectors before energization and confirm that no pins, cable shields, or housings are mechanically damaged. After connection, verify communication through the enhanced parallel interface and confirm correct channel recognition before operational data acquisition.

Bently Nevada Top Products

35003300Probe&Cable
3500/05-01-01-00-00-003300/05-22-00-00990-04-70-01-00
3500/05-01-01-05-00-013300/05-24-00-00990-04-70-02-00
3500/05-01-02-05-00-013300/45-02-01-03-00990-04-XX-01-00
3500/05-01-03-05-00-013300/45-02-02-03-00990-04-XX-03-00
3500/05-02-04-00-00-003300/48-01-01-01-00990-05-50-02-01
3500/05-02-04-00-00-013300/48-02-01-00-00990-05-70-01-00
3500/05-02-05-00-00-003300/50-01-01-00-00990-05-70-01-01
3500/05-02-05-00-00-013300/50-02-01-00-00990-05-70-02-00
3500/20 125744-023300/20-13-02-01-00-00990-05-70-03-00
3500/22 125768-013300/40-13-01-01-00-00990-05-XX-03-05

Customers Also Viewed

Bently NevadaABBYokogawaWoodwardSchneider
133835-02SPS02SPS025501-365140CPS12420
135321-01SPS03-5VSPS03-5V5501-367140NOE77101
135322-01SPS03-15VSPS03-15V9907-031140DAI55300
136751-01SPNIS21SPNIS215503-198140CRP93100
136751-02SPBRC410SPBRC4105464-658140AVI03000
184139-10SPNPM22SPNPM229907-023140CPS11420
82362-01SPDSO14SPDSO149907-162BMXDDI1602
84134-01SPFEC12SPFEC129907-028BMXNOM0200
87900-02SPDSI14SPDSI148200-1302BMXAMO0410
89998-01SPAS011SPAS0118406-003BMXAMI0810

Contact: Manski Wong +86 18030205725 manski@cambia.cn

Weight0.16 kg
Dimensions20 × 190 × 128 mm
Country Of Origin

Sweden

Condition

Brand New with Factory Sealed

Payment

T/T

Warranty

12 Months

Shipping Port

Xiamen

Reviews

There are no reviews yet.

Be the first to review “ADRE 208-P 102351-04-01 Bently Nevada Data Acquisition Interface Unit”

Your email address will not be published. Required fields are marked *

Back to Top