Overview
The FC-TDIO52 51307988-17 Honeywell FSC Series Safety Redundant Module provides dependable redundant digital I/O processing for safety-critical industrial control environments. Moreover, this module strengthens system availability by supporting fault-tolerant signal handling within Honeywell Safety Manager architectures. Therefore, safety engineers achieve stable performance even during component or channel failures.
Specification
| Parameter | Specification |
|---|---|
| Model | FC-TDIO52 |
| Order Number | 51307988-17 |
| Manufacturer | Honeywell |
| Series | FSC (Fail Safe Controller) Series |
| Module Type | Safety Redundant Digital I/O Module |
| Digital Channels | 16 channels with redundant configuration |
| Input Channels | 8 digital inputs per redundant path |
| Output Channels | 8 digital outputs per redundant path |
| Input Signal Type | 24 V DC safety digital signals |
| Output Signal Type | 24 V DC safety digital outputs |
| Channel Configuration | Configurable per channel via FSC Safety Manager |
| Electrical Isolation | System-level channel-to-system isolation |
| Diagnostics | Channel status, redundancy mismatch, fault detection |
| Communication Interface | FSC Series backplane connector |
| Energy Storage | None (no batteries or capacitive storage) |
| Power Supply | Provided via FSC system backplane |
| Power Consumption | Low-power redundant safety design |
| Mounting Method | FSC Series chassis mounting |
| Dimensions (W × H × D) | Approx. 135 × 120 × 75 mm |
| Weight | Approx. 0.7 kg |
| Operating Temperature | –5 °C to +60 °C |
| Storage Temperature | –40 °C to +85 °C |
| Relative Humidity | 5–95%, non-condensing |
| Typical Applications | Emergency shutdown, critical interlock, burner management |
| System Compatibility | Honeywell FSC Series Safety Manager systems |
FAQ
Q1: What is the primary purpose of the FC-TDIO52 51307988-17 module?
A1: The FC-TDIO52 51307988-17 provides redundant safety digital I/O functionality within Honeywell FSC Series systems.
Q2: Does the FC-TDIO52 support redundant signal paths?
A2: Yes, the module processes digital signals through redundant channels to improve safety availability.
Q3: Which systems are compatible with this module?
A3: The module integrates directly with Honeywell FSC Series Safety Manager controllers and chassis.
Q4: Does the module contain batteries or internal energy storage?
A4: No, the FC-TDIO52 51307988-17 includes no batteries or energy storage components.
Q5: Is this product new and original?
A5: Yes, all units are brand-new, original Honeywell products.
Q6: What are the shipping and return conditions?
A6: Stock is available, shipping occurs within 3 days to 2 weeks, and 30-day returns apply for quality issues.















Reviews