Overview
The Honeywell FC-BN-1608 Safe Namur Sensor Converter provides reliable signal conditioning for NAMUR proximity sensors in industrial safety systems. It converts low-level NAMUR input signals into stable, isolated output signals for distributed control systems. Moreover, its high immunity to noise ensures consistent performance in demanding environments, while its compact form enables straightforward panel or rack integration. Therefore, engineers use this module to enhance safety integrity and maintain accurate field signal monitoring.
Specification
| Parameter | Value |
|---|---|
| Product Name | Safe Namur Sensor Converter |
| Model Number | FC-BN-1608 |
| Brand | Honeywell |
| Input Type | NAMUR proximity sensor input |
| Input Current Range | Typically 1.2 mA (active) / 2.1 mA (inactive) |
| Output Type | Isolated transistor or relay output (depending on version) |
| Output Load | Up to 30 V DC, 100 mA (typical) |
| Isolation Rating | 2.5 kV between input, output, and supply |
| Supply Voltage | 24 V DC nominal |
| Power Consumption | < 1 W |
| Status Indication | LED for sensor and module status |
| Operating Temperature | –20°C to +60°C |
| Humidity Range | 5–95% RH, non-condensing |
| Mounting | DIN-rail or panel mounting |
| Housing Material | Industrial-grade reinforced polymer |
| Safety Category | Suitable for use in SIL-related applications |
FAQ
Q1: What type of sensors does the FC-BN-1608 support?
A1: It supports all standard NAMUR proximity sensors used in industrial automation.
Q2: Does the converter include electrical isolation?
A2: Yes, it provides full galvanic isolation between input, output, and supply.
Q3: Can it be used in safety-rated systems?
A3: Yes, its design supports SIL-related applications and safety loops.
Q4: How is sensor status indicated?
A4: A built-in LED displays active or fault conditions for quick verification.
Q5: What supply voltage does it require?
A5: The module operates from a 24 V DC industrial supply.
Q6: Is the FC-BN-1608 suitable for harsh environments?
A6: Yes, it withstands wide temperature ranges and high electrical noise levels.
Honeywell Top Products
Customers Also Viewed
| Bently Nevada | ABB | Yokogawa | Woodward | Schneider |
| 133835-02 | SPS02 | SPS02 | 5501-365 | 140CPS12420 |
| 135321-01 | SPS03-5V | SPS03-5V | 5501-367 | 140NOE77101 |
| 135322-01 | SPS03-15V | SPS03-15V | 9907-031 | 140DAI55300 |
| 136751-01 | SPNIS21 | SPNIS21 | 5503-198 | 140CRP93100 |
| 136751-02 | SPBRC410 | SPBRC410 | 5464-658 | 140AVI03000 |
| 184139-10 | SPNPM22 | SPNPM22 | 9907-023 | 140CPS11420 |
| 82362-01 | SPDSO14 | SPDSO14 | 9907-162 | BMXDDI1602 |
| 84134-01 | SPFEC12 | SPFEC12 | 9907-028 | BMXNOM0200 |
| 87900-02 | SPDSI14 | SPDSI14 | 8200-1302 | BMXAMO0410 |
| 89998-01 | SPAS011 | SPAS011 | 8406-003 | BMXAMI0810 |
















Reviews
There are no reviews yet.