NewSale
GE UR8LV Multilin CT/VT Module
GE UR8LV Multilin CT/VT Module Original price was: $600.00.Current price is: $501.00.
Honeywell 620-0086 UCN Parallel Link Driver Module
Honeywell 620-0086 UCN Parallel Link Driver Module Original price was: $550.00.Current price is: $489.00.

UR7JV GE PLC I/O Module datasheet. Brand New Original Stock, Modbus TCP/IP, UR Series backplane I/O extension. Global Shipping.

12 in stock

Sku:UR7JV

12 in stock

Overview

Configured for current and voltage acquisition in UR-series protection relays, the GE UR8RH (UR8RH CT/VT Module) provides direct analog signal interfacing to the Universal Relay backplane for sampled measurement processing within UR platform architectures. The GE UR8RH operates as a dedicated hardware component for transformer-scaled electrical signal acquisition in modular relay systems.

Hardware Specifications

ParameterSpecification
ModelBrandGE UR8RH
OriginUSA
Weight0.22 kg
Dimensions38 mm × 115 mm × 45 mm
OperatingTempN/A
PowerConsumptionN/A
FunctionCT/VT analog measurement interface module for UR relay backplane
InterfaceUR series internal backplane connector
Signal TypeScaled current and voltage inputs via external CT/VT circuits

Backplane Bus Communication and Firmware Compatibility

The UR8RH integrates into the GE Multilin UR backplane architecture where deterministic internal data exchange governs sampled value transport between measurement modules and relay CPU processing units. The module behavior is dependent on backplane synchronization timing and firmware revision alignment within the UR platform. Firmware flash compatibility is maintained at system level, requiring matched UR controller and module revision sets to ensure consistent CT/VT scaling interpretation and channel mapping integrity.

Frequently Asked Questions

Q: Does the UR8RH support hot-swap insertion under energized system conditions?
A: The module is not designed for live insertion in energized relay backplane configurations. System de-energization is required prior to module replacement to prevent backplane signal disturbance.

Q: What is the electrical impact of the UR8RH on backplane loading?
A: The module contributes to internal backplane communication loading only. External burden is determined by connected CT/VT circuits rather than the module itself.

Q: Is firmware alignment required between UR8RH and UR CPU modules?
A: Yes. UR platform operation requires compatible firmware versions to ensure correct scaling, channel mapping, and sampled value interpretation.

Field Installation Guidelines

The UR8RH shall be installed into the designated UR chassis slot with full mechanical seating into the backplane connector. All CT secondary circuits must remain shorted or burdened according to standard transformer safety practice prior to energization. VT inputs shall be fused according to system design to prevent overvoltage propagation into the measurement interface. Shielding conductors should be terminated at a single-point ground reference to minimize induced measurement noise. Module insertion shall be performed only after complete system power isolation.

General Electric Top Products

IC200MultilinIC660 / IC670
IC200ACC201UR9KHIC670MDL740J
IC200ALG230UR6DHIC670MDL644J
IC200ALG240UR6CHIC670CHS102A
IC200ALG321UR67HIC670ALG330
IC200MDL750UR8FHIC670GBI002
IC200MDL730UR8HHIC670MDL640
IC200MDL650UR9EHIC670CHS101
IC200CHS022URRHHIC670ALG620
IC200CPU001UR8NHIC670ALG240
IC200CPU002UR8LHIC670ALG230

Customers Also Viewed

Bently NevadaABBYokogawaWoodwardSchneider
133835-02SPS02SPS025501-365140CPS12420
135321-01SPS03-5VSPS03-5V5501-367140NOE77101
135322-01SPS03-15VSPS03-15V9907-031140DAI55300
136751-01SPNIS21SPNIS215503-198140CRP93100
136751-02SPBRC410SPBRC4105464-658140AVI03000
184139-10SPNPM22SPNPM229907-023140CPS11420
82362-01SPDSO14SPDSO149907-162BMXDDI1602
84134-01SPFEC12SPFEC129907-028BMXNOM0200
87900-02SPDSI14SPDSI148200-1302BMXAMO0410
89998-01SPAS011SPAS0118406-003BMXAMI0810

Contact: Manski Wong +86 18030205725 manski@cambia.cn

Weight0.35 kg
Dimensions10 × 80 × 20 mm
Back to Top