Overview
The Yokogawa S9562FA, also cataloged as the S9562FA Connector Unit, operates as a dedicated hardware component for physical ESB bus connection within Yokogawa Field Control Unit and ESB Bus Node Unit configurations. This connector unit is specified for use with the ANB10D Node Unit and provides a connection interface without an integrated terminator. It supports the physical interconnection requirements of the ESB bus architecture.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | S9562FA |
| Brand | Yokogawa |
| Product Type | Connector Unit without Terminator for ESB Bus |
| Compatible Node Unit | ANB10D |
| System Compatibility | Yokogawa ESB Bus Node Unit / Field Control Unit configuration |
| Primary Function | Physical ESB bus connection interface |
| Terminator | Not integrated |
| Signal Function | Supports ESB bus signal connection between compatible system components |
| Installation | Control cabinet or system hardware installation |
| Origin | Japan |
Process Control Signal and Bus Integration
The S9562FA forms part of the physical connection arrangement used in Yokogawa process control architectures. It interfaces with the ESB bus configuration associated with the ANB10D Node Unit and does not provide an integrated termination function.
Unlike analog or digital I/O modules, the S9562FA does not directly perform 4-20 mA HART loop measurement or field signal conversion. Instead, it supports the hardware connection path used by the associated control and I/O infrastructure. Therefore, installation must maintain correct connector engagement, bus continuity, shielding practice, and cable routing.
In process control systems, field-level communication technologies may include 4-20 mA HART, FOUNDATION Fieldbus, or Profibus PA depending on the connected system architecture. The S9562FA itself should be applied only according to its specified ESB bus connection function.
Frequently Asked Questions
Q: Does the Yokogawa S9562FA include an ESB bus terminator?
A: No. The provided product information identifies the S9562FA as a Connector Unit without Terminator for the ESB Bus. A separate termination arrangement must follow the applicable Yokogawa system configuration.
Q: Which node unit is identified as compatible with the S9562FA?
A: The provided technical data identifies the ANB10D as the associated Node Unit. Installation compatibility should also be verified against the complete Yokogawa system hardware configuration.
Q: Does the S9562FA directly process analog or digital field signals?
A: The provided information identifies the unit as an ESB bus connector component. It supports physical bus interconnection and is not specified as an analog input, analog output, digital input, or digital output processing module.
Field Installation Guidelines
- Verify that the S9562FA is installed in the correct position specified for the ESB bus and ANB10D Node Unit configuration.
- Confirm that the required termination arrangement is installed separately where the system architecture requires bus termination.
- Disconnect or isolate system power according to the applicable Yokogawa maintenance procedure before connecting or removing hardware.
- Inspect connectors for bent contacts, contamination, mechanical damage, or incomplete engagement before installation.
- Route communication wiring separately from high-power switching conductors where practical to reduce electrical interference.
- Maintain the system grounding and cable shielding arrangement specified for the complete control cabinet.
- Do not force the connector into an incompatible node unit or mounting position.
- Verify ESB bus continuity and system communication status after installation.
Emerson Top Products
| Emerson DeltaV | Epro | Ovation/Westinghouse |
| KJ1501X1-BC3 | 9100-00049-03 | 1C31122G01 |
| KJ3202X1-BA1 | A6110 | 1C31125G03 |
| KJ3222X1-BA1 | A6120 | 1C31232G01 |
| KJ3243X1-BA1 | A6125 | 1C31147G01 |
| KJ3002X1-BG1 | A6140 | 1B30035H01 |
| KJ3002X1-BB1 | A6210 | 1B30023H02 |
| KJ3001X1-BB1 | A6220 | 1B30023H01 |
| KJ3002X1-BC1 | A6312 | 1C31132G01 |
| KJ3002X1-BF1 | A6312/06 | 1C31129G03 |
| KJ3001X1-BJ1 | A6312/08 | 5X00119G01 |