Overview
The Honeywell TC-FCCN01, also cataloged as the TC-FCCN01 ControlNet Fiber Optic Cable Module, operates as a dedicated hardware component for electrical-to-optical signal conversion within Honeywell Experion PKS ControlNet networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | TC-FCCN01 |
| Brand | Honeywell |
| Origin | USA |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | Not specified |
| Product Type | ControlNet Fiber Optic Cable Module |
| Communication Protocol | ControlNet |
| Data Transmission Rate | 5 Mbps |
| Fiber Interface Type | Multimode Fiber |
| Supported Fiber Size | 62.5/125 um or 50/125 um |
| Optical Wavelength | Approximately 850 nm |
| Connector Type | ST Connector |
| Maximum Transmission Distance | Up to 3 km per segment |
| Storage Temperature | -40 deg C to +85 deg C |
| Relative Humidity | 5% to 95% non-condensing |
ControlNet Optical Signal Interface Characteristics
The Honeywell TC-FCCN01 performs electrical-to-optical and optical-to-electrical conversion for ControlNet communication paths. Therefore, the module allows ControlNet data transmission through fiber optic media instead of copper coaxial cable.
The fiber interface provides galvanic isolation between connected network sections. In addition, the optical transmission path reduces susceptibility to electromagnetic interference and ground potential differences in industrial installations.
The module supports ControlNet communication at 5 Mbps and uses multimode fiber with ST connectors. Furthermore, it extends network communication distance up to 3 km per fiber segment when installed according to applicable fiber specifications.
Channel-to-Channel Isolation and Process Network Integration
The TC-FCCN01 applies optical isolation technology to separate ControlNet communication nodes electrically. This configuration reduces ground loop effects and limits electrical disturbance transfer between network segments.
For Honeywell Experion PKS architectures, the module supports ControlNet infrastructure expansion between controller chassis, remote I/O assemblies, and distributed communication points. Moreover, the fiber media interface maintains deterministic ControlNet data exchange characteristics.
Frequently Asked Questions
Q: Does the TC-FCCN01 support copper ControlNet cable connection directly?
A: No. The TC-FCCN01 functions as a fiber optic media conversion module. It requires compatible fiber optic connections for optical communication segments.
Q: What fiber type does the TC-FCCN01 use for communication?
A: The module supports multimode fiber cables, including 62.5/125 um and 50/125 um fiber specifications.
Q: Does the module require special grounding for the optical interface?
A: The optical interface provides electrical isolation. However, the installed chassis and connected equipment should follow standard Honeywell grounding and shielding practices.
Field Installation Guidelines
Install the TC-FCCN01 inside the specified Honeywell control system chassis according to the applicable hardware installation documentation.
Route fiber optic cables separately from high-voltage power wiring and sources of electromagnetic interference. Avoid excessive bending, mechanical stress, and contamination of ST connector surfaces.
Verify fiber connector cleanliness before installation because optical contamination can increase signal attenuation. Maintain proper cable management and secure fiber routing to prevent mechanical damage during system operation.
Confirm ControlNet network configuration parameters after installation. Check communication status through the control system diagnostic tools before placing the network segment into normal operation.
Honeywell Top Products
| TDC3000 | FC-/FS | FSC |
| 51155128-200 | FC-SAI-1620m | 900A01-0001 |
| 51156510-100 | FC-QPP-0001 | 900B01-0001 |
| 51195066-100 | FC-USI-0001 | 900H02-0001 |
| 51195153-002 | FC-BKM-0001 | 900C32-0244-00 |
| 51195153-008 | FC-PSU-UNI2450U | 900P01-0001 |
| 51195155-100 | FC-QPP-0002 | 900G03-0102 |
| 51195156-300 | FC-RUSFDU-02 | 900H02-0102 |
| 51195191-100 | FC-TSGASH-1624P | 900B01-0101 |
| 51195199-005 | FC-PDB-0824P | 900G32-0001 |
| 51195199-010 | FC-MCAR-01 | 900A01-0102 |
Customers Also Viewed
| Bently Nevada | ABB | ROCKWELL | Woodward | Bachmann |
| 78462-01 | IMDSI14 | T8480 | 9907-164 | ISI222 |
| 78462-02 | IMHSS03 | T8442 | 5466-1000 | MPC270 |
| 79502-01 | IMASI23 | T8312-7 | 9907-167 | FS211/N |
| 79512-03 | IMDSM04 | T8153 | 5501-471 | FM211 |
| 79532-01 | TPS02 | T8830 | 5466-258 | DIO248 |
| 79748-01 | IMFCS01 | T8800 | 5464-648 | FM221 |
| 80097-01D | NTAI05 | T9310-02 | 5466-253 | DIO232 |
| 80098-01 | NTDI21-A | T8431C | 9905-969 | DIO280 |
| 16925-17 | NTHS03 | T8461C | 9905-970 | DI232 |
| 81228-01 | NTR012-A | T8151C | 9905-971 | BS204 |















Reviews
There are no reviews yet.