Overview
Configured for automatic generator synchronization in SPM-D synchronizer systems, the Woodward 8405-223 (SPM-D Digital Synchronizer) provides direct electrical execution for voltage, frequency, and phase angle matching before circuit breaker closing operations.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | Woodward 8405-223 |
| Brand | Woodward |
| Origin | United States |
| Product Type | Digital Synchronizer |
| Series | SPM-D Digital Synchronizer |
| Synchronization Function | Automatic generator to busbar or utility grid synchronization |
| Voltage Measurement Inputs | Generator voltage and busbar voltage sensing |
| Nominal Voltage Input | 100 VAC / 400 VAC AC measurement systems |
| Frequency Range | 40 Hz to 70 Hz |
| Auxiliary Supply Voltage | 24 VDC |
| Auxiliary Supply Range | 18 to 30 VDC |
| Power Consumption | Max. approx. 10 to 15 W |
| Relay Outputs | Potential-free relay contacts for breaker close and adjustment commands |
| Control Outputs | Speed raise/lower and voltage raise/lower signals |
| Display Interface | LCD with LED status indicators |
| Operating Temp | -20 deg C to +70 deg C |
| Storage Temp | -30 deg C to +85 deg C |
| Relative Humidity | 95%, non-condensing |
| Protection Class | IP54 front panel, IP20 rear side |
| Mounting Type | Flush panel mounting |
Actuator Loop Feedback Response and Synchronization Control
The Woodward SPM-D platform applies digital measurement processing to evaluate generator voltage, bus voltage, frequency deviation, and phase angle difference. Therefore, the 8405-223 unit generates correction outputs for speed and voltage control circuits before breaker closing.
The synchronizer supports actuator loop feedback response through controlled bias outputs. It adjusts frequency and voltage references through connected governor and excitation control interfaces. In addition, the controller evaluates synchronization conditions continuously to prevent breaker closing outside configured limits.
Frequently Asked Questions
Q: What signals does the Woodward 8405-223 monitor during synchronization?
A: The unit monitors generator-side voltage, busbar voltage, frequency difference, and phase angle deviation through AC sensing inputs.
Q: Does the 8405-223 directly control the generator breaker mechanism?
A: The unit provides relay contact outputs for breaker close commands. The external breaker control circuit performs the physical switching action.
Q: Can the 8405-223 operate with different generator frequencies?
A: The synchronizer supports AC systems within the configured frequency measurement range of 40 Hz to 70 Hz.
Field Installation Guidelines
- Install the unit in a panel location that provides mechanical protection and adequate airflow around the enclosure.
- Connect generator voltage and busbar voltage sensing circuits according to the approved electrical drawings.
- Use shielded cables for low-level sensing and control signal wiring where electrical noise may affect measurement accuracy.
- Ground cable shields according to site grounding standards and avoid parallel routing with high-current power cables.
- Verify auxiliary supply polarity before energizing the 24 VDC power input.
- Confirm relay output wiring for breaker close and speed/voltage adjustment circuits before commissioning.
- Perform synchronization testing by checking voltage matching, frequency matching, and phase angle conditions before connecting the generator to the bus.
Woodward Top Products
| Woodward | Woodward | Woodward |
| 9907-164 | 5453-754 | 5464-013 |
| 5466-1000 | 8440-1831 | 5466-353 |
| 9907-167 | 9907-205 | 5453-203 |
| 5501-471 | 8405-009 | 5466-318 |
| 5466-258 | 9907-014 | 5466-352 |
| 5464-648 | 9905-387 | 5466-411 |
| 5466-253 | 8273-140 | 5501-214 |
| 9905-969 | 9905-860 | 5501-365 |
| 9905-970 | 5441-693 | 5501-367 |
| 9905-971 | 5464-414 | 5501-470 |
Customers Also Viewed
| Bently Nevada | ABB | Yokogawa | Woodward | Schneider |
| 133835-02 | SPDSM04 | CP451-10 | 5463-785 | 140CPU65150 |
| 135321-01 | SPIEET800 | CP461 | 5437-672 | BMEXBP0400 |
| 135322-01 | SPINIET800 | CP461-50 | 9907-175 | 140CPU67160 |
| 136751-01 | SPNLK01 | CP451-11 | 5466-355 | 170FNT11001 |
| 136751-02 | SPSED01 | CP701 S1 | 5466-257 | 170ADO34000 |
| 184139-10 | SPSEM11 | CP345 S1 | 5466-1049 | 170ADM35010 |
| 82362-01 | SPSET01 | SCP461-11 S1 | 5501-381 | 170ADI34000 |
| 84134-01 | SPTKM01 | CP451-10 S2 | 8200-177 | 140ARI03010 |
| 87900-02 | SPTPS02 | CP401-10 | 8200-205 | BMXCPS4002 |
| 89998-01 | SPTPS13 | NFCP100-S00 | 9907-029 | 140CRP93200 |











Reviews
There are no reviews yet.