NewSale
Yokogawa ANB10D-426/CU2N/NDEL ESB Bus Node Unit
Yokogawa ANB10D-426/CU2N/NDEL ESB Bus Node Unit Original price was: $520.00.Current price is: $415.00.
Yokogawa ANB10D-125/CU2T Dual-Redundant ESB Bus Node Unit
Yokogawa ANB10D-125/CU2T Dual-Redundant ESB Bus Node Unit Original price was: $520.00.Current price is: $415.00.

ANB11D-215/BU2A/NDEL Yokogawa Optical ESB Bus Node Unit. Brand New Original Stock with Global Shipping.

10 in stock

Sku:ANB11D-215/BU2A/NDEL

10 in stock

Overview

Configured for optical ESB Bus signal transmission in Yokogawa CENTUM VP systems, the Yokogawa ANB11D-215/BU2A/NDEL (ANB11D-215/BU2A/NDEL Optical ESB Bus Node Unit) provides direct physical communication execution between distributed I/O nodes and control stations.

Hardware Specifications

ParameterSpecification
ModelANB11D-215/BU2A/NDEL
BrandYokogawa Electric Corporation
OriginJapan
Product TypeOptical ESB Bus Node Units
System PlatformYokogawa CENTUM VP DCS
Communication InterfaceDual-redundant ESB Bus
Optical InterfaceOptical ESB Bus repeater connection
Power Supply ConfigurationDual-redundant power supply
Rated Power Supply220 – 240 V AC
Frequency50/60 Hz
Connector Unit/BU2A ESB Bus Connector Unit
Software Option/NDEL Node Expansion License
Applicable ControllerAFV30 / AFV40
Mounting Type19-inch rack mounting
Operating Temp0 deg C to 60 deg C
Humidity Range5% to 95% RH, non-condensing
WeightApprox. 10 kg including I/O modules
DimensionsNot specified in available product data
Power ConsumptionApprox. 230 VA at 220 – 240 V AC
Application InterfaceDistributed I/O communication and process control networks

Yokogawa ESB Bus Communication and DCS Integration

The ANB11D-215/BU2A/NDEL manages optical ESB Bus communication between Yokogawa field I/O nodes and CENTUM VP controller systems. Moreover, the unit uses optical transmission paths to extend ESB Bus installation distance while maintaining distributed I/O connectivity.

The unit supports dual-redundant ESB Bus architecture and provides connection capability through the /BU2A ESB Bus connector unit. In addition, the /NDEL option enables node expansion functions required for compatible Yokogawa AFV30 and AFV40 configurations.

For Yokogawa process control systems, the communication design follows DCS field interface requirements, including isolated signal routing and structured I/O network expansion. Therefore, engineers can integrate the node unit into distributed control architectures with defined ESB Bus communication paths.

The Yokogawa DCS platform also commonly supports process instrumentation interfaces such as 4-20 mA HART loop protocol, FOUNDATION Fieldbus, and Profibus PA connectivity through compatible I/O modules. However, the ANB11D-215/BU2A/NDEL itself functions as an ESB Bus node communication component rather than a direct analog field input device.

Frequently Asked Questions

Q: What communication function does the ANB11D-215/BU2A/NDEL provide?
A: The unit provides optical ESB Bus node communication between Yokogawa CENTUM VP control stations and distributed I/O systems.

Q: Does the ANB11D-215/BU2A/NDEL support redundant power operation?
A: Yes. The unit supports a dual-redundant power supply configuration for continuous operation within compatible CENTUM VP installations.

Q: What is the purpose of the /BU2A and /NDEL options?
A: The /BU2A option defines the ESB Bus connector unit configuration, while the /NDEL option provides node expansion software functionality.

Field Installation Guidelines

  • Install the ANB11D-215/BU2A/NDEL inside an appropriate industrial control cabinet with suitable grounding and EMC protection.
  • Verify the AC power supply voltage before connecting the dual-redundant power input.
  • Route optical ESB Bus cables separately from high-voltage power cables to reduce electromagnetic interference risks.
  • Maintain correct fiber connection polarity and confirm optical link status during commissioning.
  • Connect cabinet grounding according to Yokogawa installation standards and local electrical regulations.
  • Confirm compatible AFV30 or AFV40 controller configuration before system startup.
  • Provide sufficient cabinet ventilation when installing multiple ESB Bus nodes and I/O modules.

Emerson Top Products

Emerson DeltaVEproOvation/Westinghouse
KJ1501X1-BC39100-00049-031C31122G01
KJ3202X1-BA1A61101C31125G03
KJ3222X1-BA1A61201C31232G01
KJ3243X1-BA1A61251C31147G01
KJ3002X1-BG1A61401B30035H01
KJ3002X1-BB1A62101B30023H02
KJ3001X1-BB1A62201B30023H01
KJ3002X1-BC1A63121C31132G01
KJ3002X1-BF1A6312/061C31129G03
KJ3001X1-BJ1A6312/085X00119G01

Customers Also Viewed

Bently NevadaABBYokogawaWoodwardSchneider
133835-02SPDSM04CP451-105463-785140CPU65150
135321-01SPIEET800CP4615437-672BMEXBP0400
135322-01SPINIET800CP461-509907-175140CPU67160
136751-01SPNLK01CP451-115466-355170FNT11001
136751-02SPSED01CP701 S15466-257170ADO34000
184139-10SPSEM11CP345 S15466-1049170ADM35010
82362-01SPSET01SCP461-11 S15501-381170ADI34000
84134-01SPTKM01CP451-10 S28200-177140ARI03010
87900-02SPTPS02CP401-108200-205BMXCPS4002
89998-01SPTPS13NFCP100-S009907-029140CRP93200

 

 

Contact: Manski Wong +86 18030205725 manski@cambia.cn

Weight10 kg
Dimensions229 × 51 × 483 mm
Country Of Origin

Sweden

Condition

Brand New with Factory Sealed

Payment

T/T

Warranty

12 Months

Shipping Port

Xiamen

Reviews

There are no reviews yet.

Be the first to review “Yokogawa ANB11D-215/BU2A/NDEL Optical ESB Bus Node Unit”

Your email address will not be published. Required fields are marked *

Back to Top