Overview
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | F9342AB |
| Brand | Yokogawa |
| Product Type | Pressure Transmitter Components |
| Origin | Japan / France |
| Sensor Technology | DPharp Silicon Resonant Sensor |
| Measurement Function | Differential, gauge, and absolute pressure measurement |
| Communication Protocol | BRAIN Protocol |
| Application | Gas, liquid, and steam pressure measurement |
| Weight | Approx. 1.18 kg |
| Dimensions | Approx. 7.6 cm x 5.1 cm x 12.7 cm |
Process Instrument Communication and Signal Processing Features
The Yokogawa F9342AB integrates DPharp silicon resonant sensing technology to convert pressure variations into stable measurement data. Therefore, the component provides repeatable pressure signal processing for connection with Yokogawa instrumentation and control platforms.
The unit supports BRAIN protocol communication for configuration and diagnostic functions. In addition, Yokogawa process instruments using this communication method can exchange measurement data with host control systems through standard field wiring interfaces.
For Yokogawa pressure measurement applications, the device supports precise sensor signal conversion and maintains measurement consistency through digital compensation functions. Furthermore, the design supports integration with DCS architectures that require continuous analog process monitoring.
Frequently Asked Questions
Q: What sensor technology does the Yokogawa F9342AB use?
A: The F9342AB uses Yokogawa DPharp silicon resonant sensor technology for pressure measurement and signal conversion.
Q: Which communication protocol does the F9342AB support?
A: The F9342AB supports the BRAIN communication protocol for parameter configuration and digital data exchange.
Q: Can the F9342AB connect directly to a Yokogawa DCS system?
A: The F9342AB functions as a pressure transmitter component and supports integration with Yokogawa process control systems through compatible instrumentation interfaces.
Field Installation Guidelines
Install the Yokogawa F9342AB according to the transmitter system wiring requirements and application documentation. Connect field cables using appropriate shielding practices to reduce electrical interference during signal transmission.
Route measurement signal cables separately from high-voltage power lines and switching circuits. Ground cable shields according to the control system grounding design to prevent unwanted noise coupling.
Verify mechanical mounting conditions before operation. Confirm that pressure connection points, impulse lines, and process fittings maintain proper alignment to avoid measurement errors caused by mechanical stress.
Check communication wiring before commissioning. Ensure that the BRAIN protocol communication path has correct polarity and stable electrical connections before performing configuration or diagnostic operations.
Emerson Top Products
| Emerson DeltaV | Epro | Ovation/Westinghouse |
| KJ1501X1-BC3 | 9100-00049-03 | 1C31122G01 |
| KJ3202X1-BA1 | A6110 | 1C31125G03 |
| KJ3222X1-BA1 | A6120 | 1C31232G01 |
| KJ3243X1-BA1 | A6125 | 1C31147G01 |
| KJ3002X1-BG1 | A6140 | 1B30035H01 |
| KJ3002X1-BB1 | A6210 | 1B30023H02 |
| KJ3001X1-BB1 | A6220 | 1B30023H01 |
| KJ3002X1-BC1 | A6312 | 1C31132G01 |
| KJ3002X1-BF1 | A6312/06 | 1C31129G03 |
| KJ3001X1-BJ1 | A6312/08 | 5X00119G01 |
Customers Also Viewed
| Bently Nevada | ABB | Yokogawa | Woodward | Schneider |
| 133835-02 | SPDSM04 | CP451-10 | 5463-785 | 140CPU65150 |
| 135321-01 | SPIEET800 | CP461 | 5437-672 | BMEXBP0400 |
| 135322-01 | SPINIET800 | CP461-50 | 9907-175 | 140CPU67160 |
| 136751-01 | SPNLK01 | CP451-11 | 5466-355 | 170FNT11001 |
| 136751-02 | SPSED01 | CP701 S1 | 5466-257 | 170ADO34000 |
| 184139-10 | SPSEM11 | CP345 S1 | 5466-1049 | 170ADM35010 |
| 82362-01 | SPSET01 | SCP461-11 S1 | 5501-381 | 170ADI34000 |
| 84134-01 | SPTKM01 | CP451-10 S2 | 8200-177 | 140ARI03010 |
| 87900-02 | SPTPS02 | CP401-10 | 8200-205 | BMXCPS4002 |
| 89998-01 | SPTPS13 | NFCP100-S00 | 9907-029 | 140CRP93200 |
















Reviews
There are no reviews yet.