Overview
Communication Features
The 1769-SM2 supports two operating modes for different drive network configurations:
- Single Mode: Supports one PowerFlex 4-class drive connection.
- Multi-Drive Mode: Supports up to five PowerFlex 4-class drive connections per channel, with 15 connections across all three channels.
Each channel uses an RJ45 connector for communication. Meanwhile, DSI/Modbus network support allows the module to exchange data with connected drives. The operating mode determines the number of drive connections available.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | 1769-SM2 |
| Brand | Allen-Bradley |
| Product Type | Communication Module |
| Product Line | CompactLogix |
| UPC | 820919134630 |
| Network Type | DSI/Modbus |
| Number of Channels | 3 |
| Channel Connector Type | RJ45 |
| Operating Modes | Single Mode and Multi-Drive Mode |
| Compatible Drive Class | PowerFlex 4-Class Drives |
| Maximum Drive Connections – Single Mode | 1 |
| Maximum Drive Connections – Multi-Drive Mode | 5 per channel; 15 total |
| Current Consumption | 350 mA at 5 VDC |
| Power Source | Compact I/O power supply |
| Operating Temperature | -10 to 50 deg C |
| Required Installation Location | Within 4 slots of the system power supply |
| Panel Mounting | Supported with screws |
| Required Mounting Screws | Two #8 or M4 panhead screws |
| DIN Rail Mounting | Supported |
| Weight | 0.75 lb (0.34 kg) |
Installation and Mounting Requirements
The module supports both DIN rail and panel mounting. For panel installation, use two #8 or M4 panhead screws. In addition, the module must be installed within four slots of the system power supply to meet the specified installation requirement.
The 1769-SM2 draws 350 mA at 5 VDC from the Compact I/O power supply. Therefore, verify the available power budget when planning the module configuration.
Frequently Asked Questions
Q: How many PowerFlex 4-class drives can the 1769-SM2 connect to?
A: In Single Mode, the module supports one drive connection. In Multi-Drive Mode, it supports up to five drives per channel, with a maximum of 15 connections across its three channels.
Q: What communication connectors does the 1769-SM2 use?
A: The module provides three RJ45 channel connectors for DSI/Modbus communication with compatible PowerFlex 4-class drives.
Q: What are the power supply and installation requirements?
A: The module draws 350 mA at 5 VDC from the Compact I/O power supply. Furthermore, install it within four slots of the system power supply and use the specified mounting hardware for panel installation.