Overview
Unlike complex rack-based systems, the 2300/20-00 is a compact, standalone monitor that integrates seamlessly with existing DCS, PLC, or SCADA systems via its configurable 4–20 mA output. This makes it ideal for facilities seeking reliable vibration protection without the overhead of large-scale systems.
Moreover, its rugged industrial design ensures consistent performance in harsh conditions while reducing maintenance costs and maximizing equipment uptime.
Specification
| Parameter | Specification |
|---|---|
| Model | 2300/20-00 |
| Product Type | Dual-Channel Vibration Monitor |
| Measurement Inputs | 2 seismic or proximity inputs (accelerometer, Velomitor, Proximitor) |
| Speed Input | 1 speed or keyphasor input for time-synchronous measurements |
| Output Signal | Configurable 4–20 mA output per channel |
| Relay Outputs | 2 or more programmable alarm relays |
| Sampling Rate | Up to 20 kHz |
| Communication Interface | 4–20 mA analog; Modbus RTU (optional) |
| Power Supply | 24 V DC nominal |
| Mounting Type | DIN rail or panel mount |
| Operating Temperature | -35°C to +70°C |
| Humidity | 95% non-condensing |
| Enclosure Rating | IP20 (DIN-rail) or IP65 (with enclosure) |
| Dimensions | Approx. 90 × 120 × 60 mm |
| Certifications | CE, CSA/NRTL, ATEX (Zone 2) |
FAQ
It supports proximity probes, accelerometers, and Velomitor velocity sensors for flexible vibration monitoring.
Q2: Can it connect directly to a PLC or DCS?
Yes, its configurable 4–20 mA outputs and Modbus interface enable seamless integration with most control systems.
Q3: Is the 2300/20-00 suitable for hazardous environments?
Yes, it carries ATEX and CSA/NRTL certifications for Zone 2 and other classified areas.
Q4: How does it differ from the 2300/25 model?
The 2300/20-00 offers 4–20 mA outputs for DCS integration, while the 2300/25 includes System 1 Classic connectivity for Trendmaster SPA systems.
Q5: What maintenance is required?
Routine sensor calibration and periodic functional checks are recommended. Self-diagnostics minimize manual intervention.
Manual/Datasheet PDF
Bently Nevada Top Products
| 3500 | 3300 | Probe&Cable |
| 3500/05-01-01-00-00-00 | 3300/05-22-00-00 | 990-04-70-01-00 |
| 3500/05-01-01-05-00-01 | 3300/05-24-00-00 | 990-04-70-02-00 |
| 3500/05-01-02-05-00-01 | 3300/45-02-01-03-00 | 990-04-XX-01-00 |
| 3500/05-01-03-05-00-01 | 3300/45-02-02-03-00 | 990-04-XX-03-00 |
| 3500/05-02-04-00-00-00 | 3300/48-01-01-01-00 | 990-05-50-02-01 |
| 3500/05-02-04-00-00-01 | 3300/48-02-01-00-00 | 990-05-70-01-00 |
| 3500/05-02-05-00-00-00 | 3300/50-01-01-00-00 | 990-05-70-01-01 |
| 3500/05-02-05-00-00-01 | 3300/50-02-01-00-00 | 990-05-70-02-00 |
| 3500/20 125744-02 | 3300/20-13-02-01-00-00 | 990-05-70-03-00 |
| 3500/22 125768-01 | 3300/40-13-01-01-00-00 | 990-05-XX-03-05 |
Customers Also Viewed
| Bently Nevada | ABB | Yokogawa | Woodward | Schneider |
| 127461-01 | IMASI03 | CP461-10 | 8446-1048 | 140CPS11420 |
| 128228-01 | IMASO01 | CP461-11 | 8444-1082 | BMXDDI1602 |
| 133811-03 | INBTM01 | CP461-51 | 5437-053 | BMXNOM0200 |
| 109548-01 | INSEM01 | CP461-E1 | 5437-054 | BMXAMO0410 |
| 128085-01 | INTKM01 | SCP461-51 S1 | 5437-080 | BMXAMI0810 |
| 128277-01 | INIIT13 | SCP461-51 S2 | 5437-173 | BMXDDO3202K |
| 176449-06 | INICT12 | SCP451-51 | 5437-524 | BMXAMO0802 |
| 74712-06 | NTCS04 | CP461-10 S1 | 5463-783 | BMXCPS2000 |
| 135799-02 | NTKU01 | CP330D S3 | 5463-786 | BMXCPS2010 |
| 136483-01 | NTAI02 | CP461-50 S2 | 5463-887 | BMXCPS3020 |
















Reviews