Woodward 9907-186 GS10 valve driver control unit. Brand New, Original Stock, Global Shipping for industrial automation applications.

22 in stock

Sku:9907-186

22 in stock

Overview

The Woodward 9907-186, also identified by the base model 9907-186, is a GS10 valve driver control unit that processes 4-20 mA position commands and provides an isolated 4-20 mA position feedback signal. It operates with an 18 to 32 VDC supply and controls the connected drive circuit according to the configured system requirements.

Hardware Specifications

ParameterSpecification
Model9907-186
BrandWoodward
Product TypeGS10 Valve Driver Control Unit
Operating Temp-20 to +55 deg C
Power ConsumptionNot specified; steady-state current: 4 A
Supply Voltage18 to 32 VDC
Steady-State Current4 A
Peak Current20 A for 50 ms
Secondary Peak Current10 A for 500 ms
Position Command4-20 mA
Position FeedbackIsolated 4-20 mA output
Signal Isolation500 VDC
Feedback Accuracy+/-0.2 mA or 1.25%
Fault Relay Rating2 A at 28 VDC, resistive load
Remote Reset Current10 to 20 mA
Maximum Interconnect LengthLess than 100 m
Drive Power WiringFour 3 mm2 conductors
Coil Resistance0.28 ohm +/-10% at 20 deg C
Coil Inductance40 mH at 60 Hz

Actuator Loop Feedback and Drive Current Characteristics

The 9907-186 uses a 4-20 mA position command for the configured drive function. Its isolated 4-20 mA feedback output provides a corresponding electrical signal for position monitoring. The specified feedback accuracy is +/-0.2 mA or 1.25%.

The power section supports a steady-state current of 4 A, a peak current of 20 A for 50 ms, and a secondary peak current of 10 A for 500 ms. These current ratings describe different operating conditions and should not be treated as continuous output ratings.

The specified coil resistance is 0.28 ohm +/-10% at 20 deg C, with an inductance of 40 mH at 60 Hz. These parameters are relevant when checking actuator compatibility and evaluating the electrical characteristics of the connected load.

Frequently Asked Questions

Q: What supply voltage does the Woodward 9907-186 require?

A: The specified supply voltage range is 18 to 32 VDC. Verify the actual supply polarity and wiring against the manufacturer’s connection documentation before energizing the unit.

Q: What position command and feedback signals does this unit support?

A: The unit accepts a 4-20 mA position command and provides an isolated 4-20 mA position feedback output. The specified signal isolation is 500 VDC.

Q: What wiring limits apply to the drive circuit?

A: The specified drive power wiring uses four 3 mm2 conductors. The maximum interconnect length is less than 100 m. Confirm the terminal assignments, conductor requirements, shielding, and grounding arrangements against the applicable wiring diagram.

Field Installation Guidelines

  1. Verify the hardware: Confirm the complete model number, terminal identification, and compatibility with the installed Woodward GS10 system before replacement or commissioning.
  2. Check the power supply: Ensure that the DC supply remains within the specified 18 to 32 VDC range under the expected operating load.
  3. Inspect drive wiring: Use conductors that meet the specified four-conductor, 3 mm2 drive power wiring requirement. Verify terminal tightness and conductor routing against the manufacturer’s documentation.
  4. Separate signal and power wiring: Route the 4-20 mA command and feedback circuits separately from high-current drive wiring where practical. Apply the manufacturer’s shielding and grounding requirements to minimize electrical interference.
  5. Verify actuator compatibility: Compare the connected coil’s resistance and inductance with the documented values of 0.28 ohm +/-10% at 20 deg C and 40 mH at 60 Hz. Confirm compatibility with the complete drive circuit before applying power.
  6. Check interconnect length: Keep the relevant interconnect within the specified limit of less than 100 m. Verify any additional cable restrictions in the system documentation.
  7. Perform commissioning checks: Before enabling the drive, inspect the command and feedback loops, confirm the fault relay wiring, and verify the configured remote reset circuit. Test the response under the approved commissioning procedure.

Woodward Top Products

WoodwardWoodwardWoodward
8237-16008273-1289907-147
8923-11828408-0059905-463
8923-12628446-10489905-068
9903-5438444-10829907-186
9905-9765437-0538440-1750
9907-1355437-0548200-226
8440-15605437-0808901-037
8441-11385437-1735463-785
LR200255437-5245437-672
LR209495463-7839907-175

Customers Also Viewed

Bently NevadaABBGE FanucYokogawaICS
131178-01TB811IC200GBI001AAI543-H10T8850
133292-01DO801 3BSE020510R1IC200MDD840AAI143-S50/K4S00T8151B
133300-01CI830 3BSE013252R1IC200MDL241AAI543-H00/A4S00T8110B
133323-01AO845A 3BSE045584R1IC200MDL243AAI143-H53/A4D00T8311
133388-01DO840 3BSE020838R1IC200MDL640AAI135-H00/K4A00T8480
133388-02CI840A 3BSE041882R1IC200MDL650ADV151-P03T8442
133396-01TB840 3BSE021456R1IC200MDL730ADV151-P00T8312-7
133442-01DI885 3BSE013088R1IC200MDL740ADV551-P00T8153
133811-02TY801K01 3BSE023607R1IC200MDL741ADV159-P00T8830
133819-01DI830 3BSE013210R1IC200MDL750ADV551-P10T8800

Contact: Manski Wong +86 18030205725 manski@cambia.cn

Weight0.0 kg
Dimensions0.0 × 0.0 × 0.0 mm
Country Of Origin

Sweden

Condition

Brand New with Factory Sealed

Payment

T/T

Warranty

12 Months

Shipping Port

Xiamen

Reviews

There are no reviews yet.

Be the first to review “9907-186 Woodward GS10 Valve Driver Control Unit”

Your email address will not be published. Required fields are marked *

Back to Top