Overview
Configured for automatic generator loading and unloading within Woodward load-sharing control networks, the Woodward 9903-543 (9903-543 Automatic Generator Loading Control Unit) provides direct electrical execution of load transfer commands between compatible governor and load-sharing controllers. It processes loading signals, applies programmable ramp control, and maintains preset base load operation while coordinating generator power transitions through analog control interfaces.
Suffix Breakdown & Model Matrix
The supplied documentation identifies Woodward 9903-543 as a fixed catalog model. No official suffix variants or option code breakdown are specified in the available technical information.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 9903-543 |
| Brand | Woodward |
| Origin | Woodward manufacturing (origin not specified) |
| Product Type | Automatic Generator Loading Control Unit |
| Compatible Systems | Woodward EG, 2301, 2500, EPG load-sharing and speed control systems |
| Input Power Supply | 12 VDC to 24 VDC |
| Load Control Function | Automatic generator loading and unloading with adjustable electronic ramp control |
| Base Load Function | Supports preset base load operation |
| Ramp Adjustment | Electronically adjustable loading and unloading rate |
| Mounting Method | DIN rail or panel mounting |
| Operating Temp | -20 deg C to +70 deg C |
| Dimensions | Approx. 8.5 in x 7.5 in x 2 in |
| Weight | Approx. 1.0 kg to 1.2 kg |
Actuator Loop Feedback Response
The 9903-543 controls generator loading by issuing progressively changing control signals rather than step changes. Consequently, actuator movement follows programmable electronic ramp settings that reduce rapid governor position changes during synchronization and load transfer. The module also maintains a predefined base load reference whenever the generator operates outside an active load-sharing sequence. Furthermore, compatibility with Woodward governor platforms allows coordinated response between the loading controller and engine speed regulation circuitry.
Frequently Asked Questions
Q: Does the 9903-543 support hot replacement while the control system remains energized?
A: The available documentation does not specify hot-swap capability. Installation or replacement should therefore be performed with the associated control equipment de-energized unless the complete control system documentation explicitly permits energized replacement.
Q: Can the loading rate be adjusted during commissioning?
A: Yes. The module provides adjustable electronic ramp control so commissioning personnel can configure generator loading and unloading rates to match system operating requirements.
Q: Which Woodward control platforms are compatible with this unit?
A: The supplied specifications identify compatibility with Woodward EG, 2301, 2500, and EPG load-sharing and speed control systems.
Field Installation Guidelines
Before installation, verify that the control cabinet power supply matches the specified 12 VDC to 24 VDC operating range. Next, mount the unit securely on a DIN rail or panel according to enclosure design requirements. Route analog control wiring separately from high-voltage power cables to reduce electrical interference. In addition, terminate cable shields according to the system grounding practice and avoid multiple shield grounding points unless required by the control architecture. Finally, confirm wiring continuity and controller configuration before placing the generator into automatic loading service.
Woodward Top Products
| Woodward | Woodward | Woodward |
| 9907-164 | 5453-754 | 5464-013 |
| 5466-1000 | 8440-1831 | 5466-353 |
| 9907-167 | 9907-205 | 5453-203 |
| 5501-471 | 8405-009 | 5466-318 |
| 5466-258 | 9907-014 | 5466-352 |
| 5464-648 | 9905-387 | 5466-411 |
| 5466-253 | 8273-140 | 5501-214 |
| 9905-969 | 9905-860 | 5501-365 |
| 9905-970 | 5441-693 | 5501-367 |
| 9905-971 | 5464-414 | 5501-470 |
Customers Also Viewed
| Bently Nevada | ABB | Yokogawa | Woodward | Schneider |
| 133835-02 | SPDSM04 | CP451-10 | 5463-785 | 140CPU65150 |
| 135321-01 | SPIEET800 | CP461 | 5437-672 | BMEXBP0400 |
| 135322-01 | SPINIET800 | CP461-50 | 9907-175 | 140CPU67160 |
| 136751-01 | SPNLK01 | CP451-11 | 5466-355 | 170FNT11001 |
| 136751-02 | SPSED01 | CP701 S1 | 5466-257 | 170ADO34000 |
| 184139-10 | SPSEM11 | CP345 S1 | 5466-1049 | 170ADM35010 |
| 82362-01 | SPSET01 | SCP461-11 S1 | 5501-381 | 170ADI34000 |
| 84134-01 | SPTKM01 | CP451-10 S2 | 8200-177 | 140ARI03010 |
| 87900-02 | SPTPS02 | CP401-10 | 8200-205 | BMXCPS4002 |
| 89998-01 | SPTPS13 | NFCP100-S00 | 9907-029 | 140CRP93200 |















Reviews
There are no reviews yet.