Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | T8310 |
| Brand | ICS Triplex |
| Product Type | Trusted Expander Processor |
| Origin | USA |
| Weight | 1.26 kg |
| Dimensions | 3 x 30.2 x 26.5 cm (Estimated Shipping Size) |
| Operating Temp | 0 deg C to +60 deg C |
| Storage Temp | -40 deg C to +85 deg C |
| Power Consumption | 24 VDC nominal input, typically 1.5 A current consumption |
| CPU Type | 32-bit microprocessor based |
| Input Voltage | 24 VDC nominal |
| Tariff Code | 8537101190 |
| Place of Shipment | Xiamen, China |
Trusted TMR Safety Control Architecture
The ICS Triplex T8310 operates within the Trusted safety system architecture and manages processor expansion functions between connected system modules. The module uses a 32-bit microprocessor platform to execute hardware-level communication and processing tasks.
Furthermore, the Trusted platform supports triple modular redundancy (TMR) 2oo3 architecture for safety-related processing environments. The architecture compares redundant processing paths and maintains fail-safe state execution when diagnostic conditions occur.
The T8310 supports controlled module interaction through the Trusted backplane environment. Therefore, system designers can integrate expansion processing functions while maintaining electrical separation and controlled signal transfer between safety system components.
Frequently Asked Questions
Q: What input voltage does the ICS Triplex T8310 require?
A: The T8310 requires a 24 VDC nominal input supply for operation.
Q: What processor technology does the T8310 use?
A: The module uses a 32-bit microprocessor based processing architecture.
Q: What are the operating environmental limits of the T8310?
A: The operating temperature range is 0 deg C to +60 deg C, with storage capability from -40 deg C to +85 deg C.
Field Installation Guidelines
Install the T8310 in the designated Trusted system rack position according to the hardware configuration requirements. Verify that the module seating mechanism fully engages with the backplane connector before applying power.
Maintain proper cabinet grounding practices and connect protective earth according to site electrical standards. Keep power wiring separated from high-voltage switching cables and sources of electromagnetic interference.
Before commissioning, confirm the 24 VDC supply polarity, module status indicators, and communication connections. Follow approved maintenance procedures when removing or replacing the module to prevent disturbance to active safety system functions.
Rockwell Automation Top Products
| ICS Triplex | ICS Triplex | ICS Triplex |
| T8431C | T8311C | TC-304-01 |
| T8461C | T8314 | T8480C |
| T8151C | T9802 | T9881 |
| T3411 | T8111 | T8122 |
| T3401 | T8403C | T8111C |
| T7420A | T8312-4 | T8312-4C |
| T7481 | T9100 | T7411F |
| T8300 | T8191 | T7481A |
| T3310 | T8312 | T8110 |
| T3411F | T8310C | T8151 |
Customers Also Viewed
| Bently Nevada | ABB | Yokogawa | Woodward | Schneider |
| 133835-02 | SPDSM04 | CP451-10 | 5463-785 | 140CPU65150 |
| 135321-01 | SPIEET800 | CP461 | 5437-672 | BMEXBP0400 |
| 135322-01 | SPINIET800 | CP461-50 | 9907-175 | 140CPU67160 |
| 136751-01 | SPNLK01 | CP451-11 | 5466-355 | 170FNT11001 |
| 136751-02 | SPSED01 | CP701 S1 | 5466-257 | 170ADO34000 |
| 184139-10 | SPSEM11 | CP345 S1 | 5466-1049 | 170ADM35010 |
| 82362-01 | SPSET01 | SCP461-11 S1 | 5501-381 | 170ADI34000 |
| 84134-01 | SPTKM01 | CP451-10 S2 | 8200-177 | 140ARI03010 |
| 87900-02 | SPTPS02 | CP401-10 | 8200-205 | BMXCPS4002 |
| 89998-01 | SPTPS13 | NFCP100-S00 | 9907-029 | 140CRP93200 |