Overview
Connection Design and Bus Interface
The T8312-4C uses four 12-pin locking ODU connectors to connect the expander interface to the expansion cables. Its SK1 chassis connection uses a double 96-way DIN 41612 C-type connector. Together, these interfaces provide the physical signal paths between the installed expander interface modules and the connected expansion chassis.
The adapter supports an expander bus data rate of 250 Mbps (0.25 Gbps). It uses the specified TC-301-01, 250 MHz communications cable. In addition, the ODU signal arrangement provides separate differential transmit and receive pairs for slices A, B and C.
Mechanical Design and Environmental Conditions
A shielded metal enclosure houses the adapter connections to support electromagnetic compatibility. The unit clips onto the rear chassis connectors, while a release button allows mechanical removal from the connection assembly.
Furthermore, the specified operating temperature is 0 to +60 deg C, with a storage range of -25 to +70 deg C. The relative humidity range is 10-95%, noncondensing.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | T8312-4 / T8312-4C |
| Brand | ICS Triplex |
| Product Type | Trusted Expander Interface Adapter |
| Compatible Controller Chassis | T8100 |
| Compatible Expander Interface | T8311 |
| Expander Connections | 4 x 12-pin locking ODU connectors |
| Chassis Connector | SK1, double 96-way DIN 41612 C-type |
| Expander Bus Data Rate | 250 Mbps (0.25 Gbps) |
| Specified Communications Cable | TC-301-01, 250 MHz |
| Enclosure | Shielded metal enclosure |
| Mechanical Retention | Rear chassis connector clips with release button |
| Operating Temperature | 0 to +60 deg C |
| Storage Temperature | -25 to +70 deg C |
| Relative Humidity | 10-95%, noncondensing |
Frequently Asked Questions
Q: What is the function of the ICS Triplex T8312-4?
A: The T8312-4 provides four physical expansion connections between the Trusted controller chassis interface and the expansion cabling. It supports the interconnection of the installed expander interface modules with remote expander chassis.
Q: Which components and cables are specified for the T8312-4?
A: The specified arrangement includes a T8100 controller chassis, T8311 expander interface and TC-301-01 communications cable. The adapter uses four 12-pin ODU connectors and a double 96-way DIN 41612 C-type chassis connector.
Q: What is the maximum specified expander bus data rate?
A: The specified expander bus data rate is 250 Mbps. The associated communications cable is TC-301-01, rated at 250 MHz.
Rockwell Automation Top Products
| ICS Triplex | ICS Triplex | ICS Triplex |
| T8431C | T8311C | TC-304-01 |
| T8461C | T8314 | T8480C |
| T8151C | T9802 | T9881 |
| T3411 | T8111 | T8122 |
| T3401 | T8403C | T8111C |
| T7420A | T8312-4 | T8312-4C |
| T7481 | T9100 | T7411F |
| T8300 | T8191 | T7481A |
| T3310 | T8312 | T8110 |
| T3411F | T8310C | T8151 |
Customers Also Viewed
| Bently Nevada | ABB | Yokogawa | Woodward | Schneider |
| 133835-02 | SPDSM04 | CP451-10 | 5463-785 | 140CPU65150 |
| 135321-01 | SPIEET800 | CP461 | 5437-672 | BMEXBP0400 |
| 135322-01 | SPINIET800 | CP461-50 | 9907-175 | 140CPU67160 |
| 136751-01 | SPNLK01 | CP451-11 | 5466-355 | 170FNT11001 |
| 136751-02 | SPSED01 | CP701 S1 | 5466-257 | 170ADO34000 |
| 184139-10 | SPSEM11 | CP345 S1 | 5466-1049 | 170ADM35010 |
| 82362-01 | SPSET01 | SCP461-11 S1 | 5501-381 | 170ADI34000 |
| 84134-01 | SPTKM01 | CP451-10 S2 | 8200-177 | 140ARI03010 |
| 87900-02 | SPTPS02 | CP401-10 | 8200-205 | BMXCPS4002 |
| 89998-01 | SPTPS13 | NFCP100-S00 | 9907-029 | 140CRP93200 |















Reviews
There are no reviews yet.