Yokogawa F3LC11-1F FA-M3 link module with RS-232-C interface, half-duplex communication and transmission speeds up to 115.2 kbps.

12 in stock

Sku:F3LC11-1F

12 in stock

Overview

The Yokogawa F3LC11-1F is a Personal Computer Link Module designed for communication between a computer and a Yokogawa FA-M3 programmable logic controller (PLC). It provides one non-isolated RS-232-C serial interface and uses half-duplex transmission with a proprietary communication protocol. The module supports configurable transmission speeds up to 115.2 kbps and provides access to PLC sequence devices, program transfer and operating status.

Communication Interface and Function

The F3LC11-1F provides an RS-232-C interface for serial communication between a personal computer and the PLC. It uses half-duplex transmission with start-stop synchronization. Furthermore, its single communication port supports transmission speeds from 300 bps to 115.2 kbps, allowing users to select a rate according to the communication requirements.

The interface uses a 9-pin female D-sub connector. Its transmission distance is limited to 15 m maximum. Meanwhile, the RS and ER control lines remain continuously ON, and the interface does not support Xon/Xoff flow control.

PLC Access and Communication Settings

The module uses Yokogawa’s proprietary communication protocol. Users can configure the transmission speed, data format, checksum, ending character and protection settings.

Its access functions cover several PLC operations, including:

  • Reading and writing sequence devices.
  • Accessing the BASIC common area.
  • Uploading and downloading ladder programs.
  • Switching the PLC between RUN and STOP.
  • Reading the PLC error log.
  • Reading the user log.

In addition, the communication format supports 7-bit or 8-bit data, one start bit, configurable parity and one or two stop bits. Error detection uses parity checking and checksum functions.

Module Installation Capacity

The maximum number of modules depends on the installed PLC CPU model. For the F3SP21 CPU, the system supports up to 2 modules. For the F3SP25, F3SP28, F3SP35, F3SP38, F3SP53, F3SP58, F3SP59, F3SP66, F3SP67, F3SP71, F3SP76, F3BP20 and F3BP30 CPUs, the maximum is 6 modules.

These limits include modules with similar functions, such as Ethernet interface modules and GP-IB communication modules (slave). Therefore, users should consider the total number of applicable communication modules when checking the available installation capacity.

Technical Specifications

ParameterSpecification
ModelF3LC11-1F
BrandYokogawa
Product TypePersonal Computer Link Module
PLC SeriesFA-M3
InterfaceEIA RS-232-C
Number of Ports1
Port IsolationNon-isolated
Transmission ModeHalf-duplex
SynchronizationStart-stop synchronization
Maximum Transmission Distance15 m
Start Bit1
Data Length7 or 8 bits
ParityNone, Even or Odd
Stop Bits1 or 2
Error DetectionParity check, checksum
Control LinesRS always ON, ER always ON
Flow ControlNo Xon/Xoff control
ProtocolProprietary protocol
Configurable SettingsTransmission speed, data format, checksum, ending character, protection
Ending CharacterYes or No
Protection FeatureYes or No
Current Consumption320 mA
External Connection9-pin female D-sub connector, M2.6 screw
Maximum Modules with F3SP212
Maximum Modules with Other Listed CPUs6
External Dimensions28.9 (W) x 100 (H) x 83.2 (D) mm
Weight110 g

Frequently Asked Questions

Q: What is the communication interface of the Yokogawa F3LC11-1F?

A: The F3LC11-1F uses one non-isolated RS-232-C serial port with a 9-pin female D-sub connector. It supports half-duplex communication and transmission speeds up to 115.2 kbps.

Q: What PLC operations can the F3LC11-1F perform?

A: The module provides access to sequence devices, the BASIC common area and ladder program transfers. Furthermore, it supports RUN/STOP control and reading both error and user logs.

Q: How many F3LC11-1F modules can be installed in one PLC system?

A: The maximum is 2 modules with an F3SP21 CPU and 6 modules with the other listed CPU models. These limits include communication modules with similar functions, such as Ethernet interface modules and GP-IB slave modules.

YOKOGAWA Top Products

CPUPower Supply and BatteryRack
CP401-10AAI543-H61AFV30S-S41151
NFCP100-S00AAI543-H10AFV30D-A41152
CP333DAAI143-S50/K4S00AFV10S-S31251
CP133E-64 S3AAI543-H00/A4S00AFV30D-S41151
CP334D S3AAI143-H53/A4D00AFV10D-S41451
CP451-11AAI135-H00/K4A00AFV30D-S41152
CP401-10ADV151-P03AFV30S-A41262
NFCP100-S00ADV151-P00AFV30S-A41252
CP333DADV551-P00AFV10D-S4115
CP451-51ADV159-P00AFV30D-A41251

Customers Also Viewed

Bently NevadaABBTriconexYokogawaOVATION
3500/42M 128229-01PM876 3BDH000607R19563-810S9342FA1C31205G01
3500/42M 138708-01PM865K02 3BSE018160R19753-110S9343FA1C31179G01
3500/42M 140734-02PM866K02 3BSE050199R19853-610S9562FA1C31181G01
3500/42M 176449-02PM891K02 3BSE053242R19761-210S9564FA1C31206G01
3500/42M-01-05PM863K01 3BSE088381R14351BS9345FA5X00070G01
3500/45 135137-01PM862K02 3BSE081636R13721S9548FA1C31224G01
3500/45 140072-02PM858K02 3BSE082896R18312S9260DE-015X00070G04
3500/45 140072-04PM861A 3BSE018158R13503ES9971DB-01C31116G04
3500/45 176449-04PM865K01 3BSE031151R1MP3101S9681DB5X00106G01
3500/50PM858AK013703ES9841DA5X00109G01

 

 

Contact: Manski Wong +86 18030205725 manski@cambia.cn

Weight0.11 kg
Dimensions28.9 × 100 × 83.2 mm
Country Of Origin

Sweden

Condition

Brand New with Factory Sealed

Payment

T/T

Warranty

12 Months

Shipping Port

Xiamen

Reviews

There are no reviews yet.

Be the first to review “F3LC11-1F Yokogawa FA-M3 Personal Computer Link Module”

Your email address will not be published. Required fields are marked *

Back to Top