- ACM11: Base communication module designation for subsystem serial interface handling
- S2: Style revision identifier defining hardware configuration variant within the ACM11 series
No further structural decoding is specified in manufacturer-provided dataset.
Hardware Specifications
| Parameter | Specification |
|---|---|
| ModelBrand | Yokogawa ACM11-S2 |
| Origin | Japan |
| Weight | Approx. 0.8 kg to 1.0 kg |
| Dimensions | 5.1 cm x 15.2 cm x 22.9 cm |
| OperatingTemp | -20 degC to +70 degC |
| PowerConsumption | Less than 1 W |
| Interface | RS-232C serial communication |
| Data Rate | Up to 230 kbps |
| Mounting Type | Control cabinet slot / dedicated base chassis |
| System Compatibility | CENTUM CS, CENTUM CS 3000, CENTUM VP |
Yokogawa DCS Serial Communication Characteristics
The ACM11-S2 implements RS-232C point-to-point serial signaling for subsystem integration under Yokogawa CENTUM architectures. Communication handling is typically coordinated through subsystem gateway functions and dedicated interface software packages used in FCS-level integration.
Channel-level electrical separation is maintained through module internal isolation design to reduce noise coupling between control backplane and external serial field wiring. Integration scenarios commonly include third-party analyzers, PLC serial ports, and legacy instrumentation using asynchronous serial framing.
The module is designed for controlled cabinet installation with defined grounding reference for RS-232 signal common, ensuring stable signal reference potential across subsystem interfaces.
Frequently Asked Questions
Q: Does the ACM11-S2 support hot-swap insertion in active CENTUM nodes?
A: Module replacement behavior depends on system configuration and chassis design. In typical CENTUM setups, maintenance insertion is performed under controlled power or redundant architecture constraints.
Q: What electrical load is imposed on the backplane interface?
A: The module is designed for low internal power consumption (< 1 W), minimizing backplane loading within FCS hardware constraints.
Q: Can RS-232C communication run concurrently with multiple subsystem devices?
A: RS-232C is a point-to-point interface; concurrent multi-device communication requires external multiplexing or higher-level subsystem gateway handling.
Field Installation Guidelines
Install the module into the designated CENTUM-compatible chassis slot with the system power isolated or under maintenance mode depending on configuration rules. Ensure RS-232C cabling uses shielded twisted conductors with single-point shield grounding at cabinet entry.
Maintain separation between serial signal wiring and high-voltage or switching power lines to reduce electromagnetic coupling. Verify connector pinout alignment before insertion to prevent interface damage.
Ground reference continuity must be established between subsystem device chassis and control cabinet reference plane to stabilize signal common mode levels.
Emerson Top Products
| Emerson DeltaV | Epro | Ovation/Westinghouse |
| KJ1501X1-BC3 | 9100-00049-03 | 1C31122G01 |
| KJ3202X1-BA1 | A6110 | 1C31125G03 |
| KJ3222X1-BA1 | A6120 | 1C31232G01 |
| KJ3243X1-BA1 | A6125 | 1C31147G01 |
| KJ3002X1-BG1 | A6140 | 1B30035H01 |
| KJ3002X1-BB1 | A6210 | 1B30023H02 |
| KJ3001X1-BB1 | A6220 | 1B30023H01 |
| KJ3002X1-BC1 | A6312 | 1C31132G01 |
| KJ3002X1-BF1 | A6312/06 | 1C31129G03 |
| KJ3001X1-BJ1 | A6312/08 | 5X00119G01 |
Customers Also Viewed
| Bently Nevada | ABB | Yokogawa | Woodward | Schneider |
| 133835-02 | SPDSM04 | CP451-10 | 5463-785 | 140CPU65150 |
| 135321-01 | SPIEET800 | CP461 | 5437-672 | BMEXBP0400 |
| 135322-01 | SPINIET800 | CP461-50 | 9907-175 | 140CPU67160 |
| 136751-01 | SPNLK01 | CP451-11 | 5466-355 | 170FNT11001 |
| 136751-02 | SPSED01 | CP701 S1 | 5466-257 | 170ADO34000 |
| 184139-10 | SPSEM11 | CP345 S1 | 5466-1049 | 170ADM35010 |
| 82362-01 | SPSET01 | SCP461-11 S1 | 5501-381 | 170ADI34000 |
| 84134-01 | SPTKM01 | CP451-10 S2 | 8200-177 | 140ARI03010 |
| 87900-02 | SPTPS02 | CP401-10 | 8200-205 | BMXCPS4002 |
| 89998-01 | SPTPS13 | NFCP100-S00 | 9907-029 | 140CRP93200 |